61
<Functions of Linkage Menu>
S1
<Edit dial>
● Select the function name
and return to the Linkage
menu by pushing the RTN
button or pushing the
Home/Exit button.
END POINT
Sets the travel, limit point, and speed of each servo.
The End Point function adjusts the left and right
servo throws, generates differential throws, and
will correct improper linkage settings.
The travel rate can be varied from 30% to 140%
in each direction on channels 1 to 12. Also, the
limit point where servo throw stops may be varied
from 0% to 155%.
Servo travel adjustment
1. Use the edit dial to move the cursor to the
"TRAV." item of the channel you want to
adjust and push the RTN button to switch to
the data input mode.
2. Turn the edit dial to adjust the rate.
Initial value: 100%
Adjustment range: 30%~140%
(When the RTN button is pushed for 1 second, the rate is
reset to the initial value.)
Push the RTN button to end adjustment and
return to the cursor move mode.
3. Repeat this procedure for each rate.
Limit point adjustment
1. Use the edit dial to move the cursor to the
"LIMIT" item of the channel you want to adjust
and push the RTN button to switch to the
data input mode.
2. Turn the edit dial to adjust the limit point.
Initial value: 135%
Adjustment range: 0%~155%
(When the RTN button is pushed for 1 second, the limit point
is reset to the initial value.)
Push the RTN button to end adjustment and
return to the cursor move mode.
3. Repeat this procedure for each limit point.
NOTE: The servo speed setting is used to set the servo delay
for each channel, from channel l to channel 12. The system
uses the programmed speed (delay) to slow down servo
position changes. The servo speed setting can be varied from
0 to 27 in each channel.
Servo speed setting
1. Use the edit dial to move the cursor to the
"SPEED" item of the channel you want to
adjust and push the RTN button to switch to
the data input mode.
2. Turn the edit dial to adjust the servo speed.
Initial value: 0
Adjustment range: 0~27 (steps)
(When the RTN button is pushed for 1 second, the servo
speed is reset to the initial value.)
Push the RTN button to end adjustment and
return to the cursor move mode.
3. Repeat this procedure for each channel.
● Select [END POINT] at the linkage menu and call the
setup screen shown below by pushing the RTN button.
(The display screen is an example. The screen
depends on the model type.)
Scrolling
● Moving cursor
● Adjusting value
● Push the S1 button
to call next page.
Содержание FMT-03
Страница 1: ...1M23Z04404 For model...