![Furuno DS-8500 Скачать руководство пользователя страница 62](http://html.mh-extra.com/html/furuno/ds-8500/ds-8500_installation-manual_2349987062.webp)
3. ADJUSTMENTS
3-18
[DS-8520 TEST (3/3)]: page 3
3.5.4
RD-502 TEST
Check the connection between DS-85 and the optional Dimmer RD-502.
[MAC ADDRESS] MAC address of transceiver unit
[00:00:00:00:00:00] to
[FF:FF:FF:FF:FF:FF]
[DIPSW]
Status DIP switch of transceiver unit
S2: [0000] to [1111]
S3: [0000] to [1111]
S5: [0000] to [1111]
[TOTAL DIST]
Total distance
[0.00] to [999999.99]
X
key
Go to page 3 of the [DS-8520 TEST].
MENU/ESC
key
Go back to [TEST] sub menu.
Item
Meaning
Range
[XDCR TEMPERATURE]
Temperature of Transducer
[-99.9] to [999.9]
([---.-]: circuit error, or no
connection to transducer)
[TRX TEMPERATURE]
Temperature of TRX board
on Transducer
[-99.9] to [999.9]
[PWR TEMP]
Temperature of PWR board
for transceiver unit
[-99.9] to [999.9]
[B VOLT]
B voltage of transceiver unit
[0.0] to [99.9]
[5 VOLT]
Voltage of 5 V for transceiv-
er unit
[0.0] to [99.9]
[12 VOLT]
Voltage of 12 V for trans-
ceiver unit
[0.0] to [99.9]
[24 VOLT]
Voltage of 24 V for trans-
ceiver unit
[0.0] to [99.9]
[FAN RPM]
Revolution of FAN
[0] to [999999]
[NOISE LEVEL (FORE/
AFT)]
Noise level of FORE/AFT
transducer
[-20] to [120.0]
[SPEED (FORE/AFT)]
Measured ship’s speed
(FORE/AFT)
[-99.99] to [99.99]
MENU/ESC
key
Go back to [TEST] sub menu.
Item
Meaning
Range
- - - . -
32 . 8ºC
25 . 5V
5 . 0V
12 . 1VA / 11. 9VD
8.3 /11 . 5 dBuV
25 .6V
4803rpm
32
. 14/
32 . 22kn
Содержание DS-8500
Страница 81: ...D 1 28 Sep 2019 H MAKI ...
Страница 82: ...D 2 28 Sep 2019 H MAKI ...
Страница 83: ...D 3 29 Oct 2019 H MAKI ...
Страница 84: ...D 4 18 Feb 2020 H MAKI ...
Страница 85: ...D 5 3 Apr 2020 H MAKI ...
Страница 86: ...D 6 6 Apr 2020 H MAKI ...
Страница 87: ...D 7 2 Apr 2020 H MAKI ...
Страница 88: ...D 8 ...
Страница 89: ...D 9 ...
Страница 90: ...D 10 ...
Страница 91: ...D 11 17 Nov 2016 H MAKI ...
Страница 92: ...D 12 25 May 2011 Y NISHIYAMA ...
Страница 93: ...D 13 15 May 2020 H MAKI ...