Fields in the SHDSLSHDSL Parameters menu
Field
Description
ATM Interface
Displays the name of the ATM interface.
Device Mode
Define the role within the connection.
Possible values:
•
6 6& && F,"
(default value):
Mode for the user page of the SHDSL connection.
•
6@ 6/ @ %"
: Mode for the provider page of the
SHDSL connection.
Note: CPE on the one hand and CO on the other hand must al-
ways be set for each SHDSL connection. Likewise, all wire pairs
have to be set to the same mode, mixed operation is not pos-
sible.
SHDSL Type
Define which Annex of ITU-T Recommendation G.991.2 is used
for the connection.
Possible values:
•
1? 1
: For applications in North America
(provider-dependent) for example.
•
1? <
(default value): For applications in Europe
(provider-dependent) for example.
Clock Rate
Define whether the clock rate should be negotiated.
Possible values:
•
7?
: The clock rate is predefined.
•
1,
(default value): The clock rate is negotiated de-
pending on the line quality.
Note that in order to use the IMA mode (see
Wire Mode
), a
fixed value has to be configured at least on one side (CO or
CPE).
Wire Mode
Define the number and combination of wires (depending on the
device type) used for the SHDSL connection.
Possible values:
Funkwerk Enterprise Communications GmbH
11 Physical Interfaces
R1xxx/R3xxx/R4xxx
141