Field
Description
calls for which no profile with a matching
Remote Hostname
can be found.
Password
Enter the password to be used for tunnel authentication. Au-
thentication between LAC and LNS takes place in both direc-
tions, i.e. the LNS checks the
Local Hostname
and the
Pass-
word
contained in the SCCRQ of the LAC and compares them
with those specified in the relevant profile. The LAC does the
same with the fields of the SCCRP of the LNS.
If this field remains empty, authentication data in the tunnel
setup messages are not sent and are ignored.
Fields in the Tunnel ProfilesLAC Mode Parameters menu
Field
Description
Remote IP Address
Enter the fixed IP address of the LNS used as the destination
address for connections based on this profile.
The destination must be a device that can behave like an LNS.
UDP Source Port
Enter how the port number to be used as the source port for all
outgoing L2TP connections based on this profile is to be de-
termined.
By default, the
Fixed
option is disabled, which means that ports
are dynamically assigned to the connections that use this pro-
file.
If you want to enter a fixed port, activate the option
Fixed
. Se-
lect this option if you encounter problems with the firewall or
NAT.
The available values are
to
'
.
UDP Destination Port
Enter the destination port number to be used for all calls based
on this profile. The remote LNS that receives the call must mon-
itor this port on L2TP connections.
Possible values are
...
'
.
The default value is
.
(RFC 2661).
The menu
Advanced Settings
consists of the following fields:
Funkwerk Enterprise Communications GmbH
18 VPN
R1xxx/R3xxx/R4xxx
307