Message ID
Severity
Message/Explanation/Solution
S0108
ERROR
%1$ is out of range. (%2$)
Explanation
A voltage error has been detected.
[[Inserted string]]%1$: Displays the types of power supply faults (VDP/VDE/VDR/VDD/VDN/3.3V
Main/12V).
[[Inserted string]]%2$: Value that represents power supply fault
Solution
Note the message contents and contact your XG1200 sales representative.
S0109
WARNING
%1$ Speed is below the Low Limit. (%2$)
Explanation
It has been detected that the speed of fan is below limit.
[[Inserted string]]%1$: Displays a location at which a fan speed error was detected.
Front Fan-1: Front fan 1
Front Fan-2: Front fan 2
Rear Fan-1: Rear fan 1
Rear Fan-2: Rear fan 2
PWR-1 Fan: Fan installed in power supply unit 1
PWR-2 Fan: Fan installed in power supply unit 2
[[Inserted string]]%2$: Fan speed.
Solution
Replace the fan unit.
P0110
INFO
%1$ Speed is good.
Explanation
The speed of fan has returned to normal.
[[Inserted string]]%1$: Identifies the fan whose normal speed has been restored.
Front Fan-1: Front fan 1
Front Fan-2: Front fan 2
Rear Fan-1: Rear fan 1
Rear Fan-2: Rear fan 2
PWR-1 Fan: Fan installed in power supply unit 1
PWR-2 Fan: Fan installed in power supply unit 2
S0111
INFO
%1$ is Removed.
Explanation
It has been detected that a fan was removed.
[[Inserted string]]%1$: Identifies which fan was removed.
Front Fan-1: Front fan 1
Front Fan-2: Front fan 2
Rear Fan-1: Rear fan 1
Rear Fan-2: Rear fan 2
PWR-1 Fan: Fan installed in power supply unit 1
PWR-2 Fan: Fan installed in power supply unit 2
P0112
INFO
%1$ is Inserted.
Explanation
It has been detected that a fan was installed.
[[Inserted string]]%1$: Identifies which fan was installed.
Front Fan-1: Front fan 1
Front Fan-2: Front fan 2
Rear Fan-1: Rear fan 1
Rear Fan-2: Rear fan 2
PWR-1 Fan: Fan installed in power supply unit 1
PWR-2 Fan: Fan installed in power supply unit 2
P0113
INFO
port %1$ Plug-In.
Explanation
It has been detected that XENPAK was installed.
[[Inserted string]]%1$: Number assigned to the port installed
P0114
INFO
port %1$ Plug-Out.
Explanation
It has been detected that XENPAK was removed.
[[Inserted string]]%1$: Number assigned to the port removed
S0115
ERROR
%1$ is not present.
Explanation
It has been detected that XENPAK was installed, but XENPAK does not respond.
[[Inserted string]]%1$: Number assigned to the port which does not respond.
Solution
Check XENPAK connection.
If the same message is displayed after taking an appropriate action, note the message contents and contact your
XG1200 sales representative.