TX140 S1
Upgrade and Maintenance Manual
183
Hard disk drives / solid state drives
7.3.4
Replacing a 3.5-inch HDD module
V
CAUTION!
●
Only remove an HDD / SSD module during operation if the drive is
not currently being accessed. Observe the indicators for the
corresponding HDD / SSD modules, see "PRIMERGY TX140 S1
Server Operating manual".
●
Under no circumstances should you remove an HDD / SSD module
while the system is in operation if you are not sure that the drive is
operated by a RAID controller and belongs to a disk array that is
operating in RAID level 0, 1, 1E, 10, 5, 50, 6 or 60.
An HDD / SSD module can only be replaced during operation in
conjunction with a corresponding RAID configuration.
●
All HDD / SSD modules (drives) must be uniquely identified so that
they can be reinstalled in their original mounting locations later. If this
is not done, existing data can be lost.
7.3.4.1
Required tools
●
Preliminary and concluding steps: tool-less
●
Replacing a 3.5-inch HDD module: tool-less
7.3.4.2
Preliminary steps
Before replacing a 3.5-inch HDD module, perform the following steps:
Ê
If applicable, open the rack door as described in section
"Opening the rack
door" on page 61
.
Ê
Locate the defective server as described in section
"Locating the defective
server" on page 54
.
Ê
When working on a tower server, open the HDD bay cover as described in
section
"Removing the HDD bay cover" on page 76
.
Customer Replaceable Units (CRU)
Average task duration: 5 minutes
Содержание PRIMERGY TX140 S1
Страница 6: ...Upgrade and Maintenance Manual TX140 S1 ...
Страница 22: ...Upgrade and Maintenance Manual TX140 S1 Contents ...
Страница 24: ...24 Upgrade and Maintenance Manual TX140 S1 ...
Страница 40: ...40 Upgrade and Maintenance Manual TX140 S1 Before you start ...
Страница 204: ...204 Upgrade and Maintenance Manual TX140 S1 Hard disk drives solid state drives ...
Страница 292: ...292 Upgrade and Maintenance Manual TX140 S1 Expansion cards and backup units ...
Страница 306: ...306 Upgrade and Maintenance Manual TX140 S1 Main memory ...
Страница 370: ...370 Upgrade and Maintenance Manual TX140 S1 Accessible drives ...
Страница 414: ...414 Upgrade and Maintenance Manual TX140 S1 Front panel and external connectors ...
Страница 472: ...472 Upgrade and Maintenance Manual TX140 S1 System board and components ...
Страница 568: ...568 Upgrade and Maintenance Manual TX140 S1 Cabling ...