Main memory
10.4.5 Concluding steps
Perform the following procedures to complete the task:
Ê
Reinstall the fan module as described in section
"Installing the fan module"
on page 209
.
Ê
Close the side / top cover as described in section
"Mounting the top cover"
on page 80
(rack server) or
"Mounting the side cover" on page 85
(tower
server).
Ê
When working on a rack-mounted server, secure it in the rack as described
in section
"Sliding the server into the rack" on page 89
.
If the server has been completely removed from the rack for maintenance
purposes, reinstall and secure it in the rack as described in section
"Mounting the server in the rack" on page 87
.
Ê
Reconnect the AC power cord to the power supply unit and secure it with a
cable tie as described in section
"Connecting the server to the mains" on
page 90
.
Ê
If applicable, close the rack door as described in section
"Closing the rack
door" on page 92
.
Ê
If available, update the system board BIOS to the latest version as described
in section
"Updating or recovering the system board BIOS and iRMC" on
page 100
.
Ê
Enable boot watchdog functionality as described in section
"Enabling SVOM
boot watchdog functionality" on page 110
.
Ê
Enable the replaced memory module(s) as described in section
"Enabling
replaced components in the system BIOS" on page 111
.
Ê
Verify if the memory mode has been restored to its original state as
described in section
"Verifying the memory mode" on page 111
.
Ê
If BitLocker functionality is used and has been disabled before starting the
maintenance task, re-enable BitLocker as described in section
"Enabling
BitLocker functionality" on page 116
.
Содержание PRIMERGY TX140 S1
Страница 6: ...Upgrade and Maintenance Manual TX140 S1 ...
Страница 22: ...Upgrade and Maintenance Manual TX140 S1 Contents ...
Страница 24: ...24 Upgrade and Maintenance Manual TX140 S1 ...
Страница 40: ...40 Upgrade and Maintenance Manual TX140 S1 Before you start ...
Страница 204: ...204 Upgrade and Maintenance Manual TX140 S1 Hard disk drives solid state drives ...
Страница 292: ...292 Upgrade and Maintenance Manual TX140 S1 Expansion cards and backup units ...
Страница 306: ...306 Upgrade and Maintenance Manual TX140 S1 Main memory ...
Страница 370: ...370 Upgrade and Maintenance Manual TX140 S1 Accessible drives ...
Страница 414: ...414 Upgrade and Maintenance Manual TX140 S1 Front panel and external connectors ...
Страница 472: ...472 Upgrade and Maintenance Manual TX140 S1 System board and components ...
Страница 568: ...568 Upgrade and Maintenance Manual TX140 S1 Cabling ...