RX200 S8
Upgrade and Maintenance Manual
47
Basic hardware procedures
4.3
Disconnecting the server from the mains
Figure 2: Unlocking the cable clamp of a power supply unit
Ê
Press the cable clamp down until it disengages (1).
Ê
Open the cable clamp (2).
Ê
Pull all power cords out of the power outlets and remove them from the cable
clamps.
4.4
Getting access to the component
V
CAUTION!
●
Before removing or installing covers, turn off the server and all
peripheral devices. Also unplug all power cables from the outlet.
Failure to do so can cause electric shock.
●
In order to comply with applicable EMC regulations (regulations on
electromagnetic compatibility) and satisfy cooling requirements, the
server must not run while the top cover is removed.
●
For further safety information, please refer to chapter
"Important
information" on page 31
.
/
0