116
Upgrade and Maintenance Manual
RX200
S8
Hard disk drives / solid state drives
An HDD/SSD module can only be replaced during operation in
conjunction with a corresponding RAID configuration.
●
All HDD/SSD modules (drives) must be uniquely identified so that
they can be reinstalled in their original bays later. If this is not done,
existing data can be lost.
V
Only applicable for removing non-defective HDD/SSD modules:
Ê
Set the drive to "Offline" via the software (RAID controller
configuration software), before removing an HDD/SSD module that is
not defective.
7.4.1
Preliminary steps
Ê
"Locating the defective server" on page 43
Ê
"Locating the defective component" on page 45
7.4.2
Removing the defective 2.5-inch HDD/SSD module
Ê
Remove the HDD/SSD module as described in section
"Removing the 2.5-
inch HDD/SSD module" on page 114
.
7.4.3
Installing the new 2.5-inch HDD/SSD module
Ê
Install the HDD/SSD module as described in section
"Installing the 2.5-inch
HDD/SSD module" on page 112
.
7.4.4
Concluding steps
Ê
"Performing a RAID array rebuild" on page 84
Содержание PRIMERGY RX200 S8
Страница 30: ...30 Upgrade and Maintenance Manual RX200 S8 Before you start ...
Страница 42: ...42 Upgrade and Maintenance Manual RX200 S8 Important information ...
Страница 106: ...106 Upgrade and Maintenance Manual RX200 S8 Power supply ...
Страница 130: ...130 Upgrade and Maintenance Manual RX200 S8 Hard disk drives solid state drives ...
Страница 194: ...194 Upgrade and Maintenance Manual RX200 S8 Expansion cards and backup units ...
Страница 210: ...210 Upgrade and Maintenance Manual RX200 S8 Main memory ...
Страница 234: ...234 Upgrade and Maintenance Manual RX200 S8 Processors ...
Страница 244: ...244 Upgrade and Maintenance Manual RX200 S8 Optical disk drive ...
Страница 320: ...320 Upgrade and Maintenance Manual RX200 S8 Cables ...