Hard disk drives / solid state drives
7.6.2
Removing the defective 8xHDD backplane
Ê
Release all HDD/SSD modules and pull them out a few centimeters, see
section
"Removing the 2.5-inch HDD/SSD module" on page 114
I
The HDD/SSD modules need not to be completely removed. But if
you want to completely remove them nevertheless, check if all
HDD/SSD modules are uniquely identified so that you can reinsert
them into their original bays.
Figure 49: Disconnecting cables from the 8xHDDbackplane
Ê
Disconnect the following cables from the 8xHDD backplane:
– (1) SAS data cable channel A from connector "CN1"
– (2) power cable from connector "CN20"
– (3) I
2
C cable (HDD monitoring) from connector "CN14" (if applicable)
Ê
Disconnect the SAS data cable (4) from the RAID controller connector
"MLC1".
For the cable plan see section
"Cabling" on page 314
.
Ê
Remove all fan modules as described in section
"Removing the defective
fan module" on page 133
.
I
Check if all fan modules are uniquely identified so that you can
reinsert them into their original bays.
Содержание PRIMERGY RX200 S8
Страница 30: ...30 Upgrade and Maintenance Manual RX200 S8 Before you start ...
Страница 42: ...42 Upgrade and Maintenance Manual RX200 S8 Important information ...
Страница 106: ...106 Upgrade and Maintenance Manual RX200 S8 Power supply ...
Страница 130: ...130 Upgrade and Maintenance Manual RX200 S8 Hard disk drives solid state drives ...
Страница 194: ...194 Upgrade and Maintenance Manual RX200 S8 Expansion cards and backup units ...
Страница 210: ...210 Upgrade and Maintenance Manual RX200 S8 Main memory ...
Страница 234: ...234 Upgrade and Maintenance Manual RX200 S8 Processors ...
Страница 244: ...244 Upgrade and Maintenance Manual RX200 S8 Optical disk drive ...
Страница 320: ...320 Upgrade and Maintenance Manual RX200 S8 Cables ...