114
Upgrade and Maintenance Manual
RX200
S8
Hard disk drives / solid state drives
7.3.2
Removing the 2.5-inch HDD/SSD module
Figure 44: Unlocking the 2.5-inch HDD/SSD module
Ê
Release the locking mechanism as follows:
1. Press the two green tabs of the locking lever together (1).
2. Push the handle of the HDD/SSD module fully in the direction of the
arrow (2). The HDD/SSD module is now unlocked.
Ê
Pull the HDD/SSD module out a few centimeters.
Ê
Wait for at least 30 seconds.
I
This is not necessary when removing a solid state drive.
I
This period is necessary for the RAID controller to recognize that an
HDD module has been removed and for the hard disk drive to come
to a stop.
Ê
Pull the HDD/SSD module out completely.
/
/