System board and components
Figure 240: Installing the fan cage
Ê
Insert the fan cage (1).
Ê
Push the fan cage somewhat in direction of the arrow (2) to engage the
hooks (see close-up).
Ê
Fasten fan cage with the four screws (3).
Ê
Reconnect all cables to the system board:
– Two power cables of power supply
– Front panel cable
– Power cable for HDD backplane
– SATA cables for HDD backplane (if applicable)
– SATA cable for ODD (if applicable)
– Front VGA cable (if applicable)
– I
2
C cable (HDD monitoring) (if applicable)
For the cable plan see section
"Cabling" on page 314
.