328
Upgrade and Maintenance Manual
RX200
S8
Appendix
The LEDs have the following meaning:
LED Indicator
Meaning
A - Identification blue on
server is identified via the ServerView
Operations Manager
blue flashing
local monitor off
B - CSS
(Customer Self
Service)
off
no error (CSS component)
yellow on
indicates a prefailure (CSS component)
yellow flashing indicates a failure (CSS component)
C - GEL
(Global Error
LED)
off
no error (non CSS component)
orange on
indicates a prefailure (non CSS
component)
orange flashing indicates a failure of a non CSS
component.
Reasons for a failure may be:
– over temperature measured by one of
the sensors
– sensor is defective
– CPU error
– software detected an error
F - Controller
off
PCI card okay
orange on
PCI card failure (PCI card installed on riser
card)
G - CPU
off
CPU okay
orange on
CPU failure
H - Memory
module
off
memory module running
orange on
memory module failure
I - iRMC
off
iRMC S4 inactive
green flashing
iRMC S4 okay
K - Fans
off
fan running
orange on
fan failure
L - Battery
off
battery running
orange on
battery failure
Содержание PRIMERGY RX200 S8
Страница 30: ...30 Upgrade and Maintenance Manual RX200 S8 Before you start ...
Страница 42: ...42 Upgrade and Maintenance Manual RX200 S8 Important information ...
Страница 106: ...106 Upgrade and Maintenance Manual RX200 S8 Power supply ...
Страница 130: ...130 Upgrade and Maintenance Manual RX200 S8 Hard disk drives solid state drives ...
Страница 194: ...194 Upgrade and Maintenance Manual RX200 S8 Expansion cards and backup units ...
Страница 210: ...210 Upgrade and Maintenance Manual RX200 S8 Main memory ...
Страница 234: ...234 Upgrade and Maintenance Manual RX200 S8 Processors ...
Страница 244: ...244 Upgrade and Maintenance Manual RX200 S8 Optical disk drive ...
Страница 320: ...320 Upgrade and Maintenance Manual RX200 S8 Cables ...