RX200 S8
Upgrade and Maintenance Manual
45
Basic hardware procedures
4.1.3
Locating the defective component
After determining the error class by the CSS or Global Error indicators (see
section
"Determining the error class" on page 44
) local diagnostic indicators on
the system board, HDD modules and power supply units allow you to identify
the defective component (see section
"Connectors and indicators" on
page 325
).
I
For further information, refer to the "ServerView Suite Local Service
Concept (LSC)" manual.
4.1.3.1
Local diagnostic indicators on the front
Ê
Check the CSS indicator on the front and connector panels of the server:
I
In addition to local diagnostic indicators, CSS or Global Error LEDs
indicate, if the defective component is a customer or field replaceable
unit (see section
"Determining the error class" on page 44
).
4.1.3.2
Local diagnostic indicators on the system board
Using the Indicate CSS button
Ê
Shut down and power off the server.
Ê
Disconnect the AC power cord(s) from the system.
I
It is mandatory to disconnect power cords in order to use the Indicate
CSS functionality.
Ê
Press the Indicate CSS button to highlight defective components (see
section
"Connectors and indicators" on page 325
).
I
In addition to local diagnostic indicators, CSS or Global Error LEDs
indicate, if the defective component is a customer replaceable unit or if a
service technician needs to be dispatched to replace the part (see
section
"Determining the error class" on page 44
).
If the system has been powered off to replace a non hot-plug unit, a
system of PRIMERGY diagnostics indicators guides you to the faulty
component.
Содержание PRIMERGY RX200 S8
Страница 30: ...30 Upgrade and Maintenance Manual RX200 S8 Before you start ...
Страница 42: ...42 Upgrade and Maintenance Manual RX200 S8 Important information ...
Страница 106: ...106 Upgrade and Maintenance Manual RX200 S8 Power supply ...
Страница 130: ...130 Upgrade and Maintenance Manual RX200 S8 Hard disk drives solid state drives ...
Страница 194: ...194 Upgrade and Maintenance Manual RX200 S8 Expansion cards and backup units ...
Страница 210: ...210 Upgrade and Maintenance Manual RX200 S8 Main memory ...
Страница 234: ...234 Upgrade and Maintenance Manual RX200 S8 Processors ...
Страница 244: ...244 Upgrade and Maintenance Manual RX200 S8 Optical disk drive ...
Страница 320: ...320 Upgrade and Maintenance Manual RX200 S8 Cables ...