![Fujitsu Primergy RX100 S3 Скачать руководство пользователя страница 280](http://html.mh-extra.com/html/fujitsu/primergy-rx100-s3/primergy-rx100-s3_user-manual_121070280.webp)
280
C Remote Control Function and Console Redirection
■
Connection
1
Connect the serial port connector 1 to the management terminal using an RS-
232C cross cable.
2
Establish connection using the terminal software.
■
Operation on the Server
Perform the following operation in the terminal software on the management terminal.
1
Establish connection using the terminal software and press the [Enter] key.
The following message appears.
2
Enter the following command.
Remote [Enter]
The following message appears.
3
Enter the following command.
Remote [Enter]
The following menu appears.
The "State" line in the message will show either of the following.
Login>
Password>
table: Messages in the Main Menu Window
Message
Status
ON
The server is turned on.
OFF
The server is turned off.
REMOTE MAINTENANCE MENU
(1) Immediate Power Down
(2) Immediate Reset
(3) Graceful Power Down
(4) Power Cycle
(5) Power On
(6) View System Eventlog (SEL)
Enter selection or (0) to quit:
*******************************************
Welcome to System RX100 S3
BMC FW: *.** SDRR: *.**
State: Off (na = Currently not available)
*******************************************
Содержание Primergy RX100 S3