![background image](http://html.mh-extra.com/html/fujitsu/primergy-rx100-s3/primergy-rx100-s3_user-manual_121070245.webp)
245
PRIMERGY RX100 S3 User’s Guide
9
O
p
eration
a
nd
Mainten
ance
When the message is "OK. You can boot system. Please check HDD status after
boot."
The hard disk unit has a failure or is in the process of rebuilding. Remove the failed hard disk unit
according to the following procedure:
1. Confirm the "Previous Physical Disk States" field and the "Current Physical Disk
States" field displayed on the screen.
The ID, for which "Failed" is displayed for both "Previous Physical Disk States" and
"Current Physical Disk States", is the ID for the failed hard disk unit.
2. Touch a metal part of the server to discharge static electricity.
3. Pull out the handle upward 90 degrees, pull out the failed hard disk unit confirmed
in step 4 by only 1 to 3 cm, and disconnect it from the SCSI bus.
Do not pull out the hard disk unit fully from the server.
4. Wait for approximately a minute (until the hard disk unit's motor stops rotating).
5. Pull out the failed hard disk unit from the hard disk bay.
6. Remove the "On Board RAID Utility" floppy disk from the floppy disk drive.
7. Press the [Ctrl]+[Alt]+[Delete] keys and restart the OS.
The following message is displayed once again at the POST. Press the [Ctrl]+[A] key and
close the message.
If one of the hard disk units fails, the status for the logical drive becomes "Critical" and the drive
is put under non-redundant operation. When you repeat the startup with one hard disk unit
removed, the system pauses with the message every time during the startup.
Install a new hard disk unit in the removed hard disk unit bay and execute "Rebuild" as soon as
possible.
While continuing the operation with one hard disk unit failed, if the second hard disk unit fails, the
system may start up from the first failed hard disk unit depending on the type of hard disk failure. In this
case, the system starts using old data and the latest data can be lost. In order to avoid this problem,
follow the procedures above to check the hard disk status before starting the OS.
●
When an Event Log Is Detected at Startup (in Array Configuration with the
Onboard SCSI Controller)
When you configure a disk array with the onboard SCSI controller and use Windows Server 2003 or
Windows 2000 Server as the domain controller, the following warning message may be logged in the OS
event log at the startup.
Warning!: The array is degraded. Press [Ctrl]
[A] to continue after insert Floppy Disk.
Event Type: Warning
Event Source: Disk
Description: The driver detected that the device \Device\Harddisk0\DR0
has its write cache enabled. Data corruption may occur.