Troubleshooting and Tips
Drive Reported as Defective
Ê
Switch OFF the corresponding server blade and physically replace the
defective hard disk drive with an identical model (see “Installing an
Additional Hard Disk Drive” on page 83).
Ê
Reboot the server blade and enter the
FastBuild (tm) Utility Main Menu
.
Ê
Select the
Rebuild Array
option
[5]
. The array in the
Critical
status will be
displayed.
Ê
Highlight the array and press
[Enter]
. A new screen will then appear.
Ê
Under
[Select Drive for Rebuild]
, highlight the replacement (new)
drive. The ID of this drive must be set to “Slave”.
V
CAUTION!
All drive data will be overwritten.
Make sure you choose the correct drive and have defined the new,
blank drive as a “Slave” drive.
Ê
Press
[Enter]
and confirm that the data will be copied to the selected drive.
All data on the replacement drive will be overwritten with mirrored infor-
mation from the array drive. A progress bar will appear.
Once the rebuild process is complete, the user will be asked to reboot the
system.
Ê
Reboot the server blade.
Channel
Slot no.
ID
1
0
Master
2
1
Table 5: HDD Channel: ID and Corresponding Location (Slot no.) on the Server Blade
Содержание PRIMERGY BX300
Страница 4: ......
Страница 6: ......
Страница 10: ......
Страница 20: ......
Страница 47: ...A26361 K863 Z102 8 7619 Rev 8 0 37 Installing the Hardware Cabling the System Figure 12 Cable routing ...
Страница 72: ......
Страница 78: ......
Страница 80: ......
Страница 120: ......
Страница 134: ......
Страница 142: ......
Страница 150: ......
Страница 158: ......
Страница 160: ......
Страница 162: ......