Chapter 8 Operational Settings
198
Example 1:
Position: Middle
Selected range = Enable, Start = 50 mm, End = 200 mm
Multifeeds are detected only within the area of light blue.
Start
(Middle)
Displays the start position of the detection
by the length from the leading edge of the
document.
Range: 0 to 510 mm, in 2 mm increments,
Start<End
End
(Middle)
Displays the end position of the detection
by the length from the leading edge of the
document.
Range: 0 to 510 mm, in 2 mm increments,
Start<End
HINT
When both [Start] and [End] are set to "0", multifeed detection is
performed for the whole area regardless of whether it is
enabled or disabled.
To disable multifeed detection for the whole document, select
[Disable] and set the start position to "0" and the end position to
equal the document length or longer.
If you set a value larger than the document length for the start
position, selecting [Disable] detects the whole length of the
document and selecting [Enable] disables the multifeed
detection.
To detect multifeeds, the detection range must be at least 5 mm
in length.
Configure the setting so that the value of the end position minus
the start position is 6 mm or more.
You can also set the start and the end positions by the following
methods:
- Draw an area with the mouse on the displayed image.
- Drag the handles for [Start] and [End] positions on the
displayed image.
Range
Description
Unit: mm
35
50
200
Feed
Direction