Chapter 5 Daily Care
110
Feed Roller (× 2)/Eject Roller (× 2)
The power must be turned on to rotate the feed/eject rollers.
1 Plug in the power cable and turn on the scanner.
For details, refer to
"1.3 Turning the Power ON/OFF" (page 23)
.
The [Ready] screen is displayed on the LCD.
2 Press the [Menu] button.
The [Settings Menu] screen is displayed on the LCD.
3 Press the [
] or [
] button and select [2: Cleaning], then press the
[Scan/Enter] button to confirm.
The [Cleaning] screen is displayed on the LCD.
4 Press the [
] or [
] button and select [2: Roller Wipe], then press
the [Scan/Enter] button to confirm.
A message is displayed on the LCD.
5 Open the ADF.
For details, refer to
"1.4 Opening/Closing the ADF" (page 24)
.
6 When you press the [Scan/Enter] button, the feed/eject rollers
rotate a certain amount.
7 Put a piece of cloth moistened with Cleaner F1 or a sheet of
Cleaning Wipe against the surface of the feed rollers/eject rollers,
and wipe horizontally.
Wipe off any dirt or dust on the surface by pressing the [Scan/
Enter] button to rotate the rollers.
Make sure that it is wiped properly because black residue on the
roller will affect the feeding performance.
As a guideline, pressing the [Scan/Enter] button seven times will
rotate the feed/eject rollers one revolution.
ATTENTION
Do not perform scanning from the scanner driver during
cleaning.
When the ADF is open, it might close
accidentally. Be careful not to get your
fingers caught.
Menu
Scan/Enter
Check
Power
Stop/Clear
[Scan/Enter] Button
[fi-7600]
When you press the [Scan/Enter] button,
the feed/eject rollers rotate at the same
time. Be careful not to touch the rollers
with your hand while they are rotating.
Menu
Scan/Enter
Check
Power
Stop/Clear
[Scan/Enter] Button
[fi-7700/fi-7700S]