Chapter 5 Setup
5.6 Completion of the ETERNUS DX Disk Storage System Setup and Power Off
FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Installation-
129
Copyright 2014 FUJITSU LIMITED
P3AM-5502-05ENZ0
This section explains how to use the Power switch to turn off the ETERNUS DX Disk storage
system. For details on how to turn off the power via the power synchronized unit, refer to the
related manuals.
Procedure
1
Press and hold the console panel's power switch ( ) for 4 seconds or longer.
The READY LED should turn off.
2
The ETERNUS DX Disk storage system power is turned off.
When the power is turned off, the POWER LED will go out.
End of procedure
IMPORTANT
•
When turning off the ETERNUS DX Disk storage system, the power
shuts off after the data in the cache memory is written to the disks.
Therefore, it may take one minute (maximum six minutes) for the power
supply to be completely turned off.
•
Do not turn off the power of the ETERNUS DX Disk storage system, the
network devices that connect the ETERNUS DX Disk storage system,
or the server while the server is operating, as this may result in the loss
of data or prevent data from being saved.
•
When using a power synchronized unit for power control, make sure to
turn off the power with the server. Even if the ETERNUS DX Disk
storage system is turned off by using the Power switch, the power
synchronization function automatically turns on the power.
IMPORTANT
Press the power switch only once. If the power switch is pressed
again while either the POWER LED or the READY LED is on, the
ETERNUS DX Disk storage system power may turn on.
When a drive enclosure is installed, the power turns off automatically.
Controller Enclosure
Drive Enclosure
Power switch