6. OUTDOOR FAN CONTROL
01-07
( Table8 : Outdoor fan speed )
* The outdoor fan speed mentioned above depends on the compressor frequency.
(When the compressor frequency increases, the outdoor fan speed also changes to the higher
speed. When the compressor frequency decreases, the outdoor fan speed also changes to the
lower speed.)
* After the defrost control is operated on the heating mode, the fan speed keeps at the higher speed
as table9 without relating to the compressor frequency.
( Table9 : Outdoor fan speed after the defrost )
1. Outdoor Fan Motor
2. Fan Speed
AC Motor
DC Motor
ASYA09/ 12LEC
Following table shows the type of the outdoor fan motor. The control method is different
between AC motor and DC motor.
( Table7 : Type of Motor )
ASYA09LEC
850rpm
Cooling
Heating
ASYA09LEC
ASYA12LEC
D
F
Zone
850/ 750/ 670/ 500
850/ 750/ 680/ 550/ 450
900/ 750/ 680/ 550/ 450
Refer to Fig.9
(rpm)
400/ 280
G
250/ 200
400/ 280
250/ 200
D
F
400/ 280
850/ 750/ 670/ 500
250/ 200
G
Dry
760/ 470
400/ 280
250/ 200
760/ 470
ASYA12LEC
900rpm
( Fig.9 : Outside air temperature zone selection )
12
°
C
0°
C
Outside air
temperature rises
Outside air
temperature drops
F zone
D zone
G zone
2
°
C
10
°
C