03-02
( Factory setting)
Setting Description
Function Number
Setting Value
No
Yes
42
00
01
1-4. Setting the Indoor room temperature sensor switching function
(Only for Wired remote controller)
The following settings are needed when use the control by
Wired remote controller temperature sensor.
( Factory setting)
Setting Description
Function Number
Setting Value
A
B
C
D
44
00
01
02
03
1-5. Setting the Remote controller signal code
Change the indoor unit Signal Code, depending on the remote controllers.
* If setting value is "00" : Room temperature is controlled by the indoor unit temperature sensor.
* If setting value is "01" : Room temperature is controlled by remote controller unit sensor.