![Fujitsu AIRSTAGE V-II Скачать руководство пользователя страница 446](http://html.mh-extra.com/html/fujitsu/airstage-v-ii/airstage-v-ii_design-and-technical-data_118213446.webp)
553555 NETWORK CONVERTOR
MODEL : UTY 5 VGGX
To be used for connecting single split type system with VRF system
[ A change of DIP switch setting is necessary]
FEATURES
FUNCTIONS
●Start/Stop ●Temperature control ●Operation mode ●Timer setting
●Fan control ●Central control (Lock the remote controller functions)
SYSTEM DIAGRAM
*1 : When connecting an indoor unit that has an 'L' control method, connect the remote controller for VRF to control from a wired remote controller. Do not
connect the wired remote controller included with the indoor unit.
*2 : Connect one big multi system to one network convertor. Don't connect two big multi system, or one big multi system and one single split system to one
network convertor.
*3 : All indoor units connected to a network convertor are operating under same status.
*4 : For controlling J series system, same operation mode should be used in same refrigerant system. When indoor unit is set in different operation mode via
central control unit, indoor unit might be in stand by mode.
*5 : For using J series heat pump system, "AUTO" and "FAN" mode should not be used.
*6 : Network convertor is necessary for each indoor unit.
With this network convertor, single split type, big multi type and J series
●
air conditioners can be controlled by Touch panel controller, System
controller in VRF network system or by wired remote controller that is
connected to the Network convertor.
Start/Stop, operation mode, temperature setting, fan speed, etc. can be
●
done with these controllers.
One Network convertor can be connected and controlled up to 16
●
indoor units.
2 wired remote controllers are possible for one network convertor.
●
Up to 100 network convertors can be connected in one VRF network
●
system. (One Network convertor is regarded as one refrigerant system.
The total refrigerant systems in one VRF network system must be
within 100.)
Group of Single Split System
*3
Single Split
System
VRF system
Big Multi System
*2
*3
J Series System
*4
*5
*6
VRF
Outdoor unit
VRF
J series
Outdoor unit
Outdoor unit for
big multi
Outdoor unit for
single split system
Indoor unit
Touch panel
controller
Wired remote*1
controller
Transmission line
(non-polar 2-conductor)
Remote
controller line
Network
convertor
- (05 - 58) -
C
O
N
TRO
L
SY
ST
EM
C
O
N
TRO
L
SY
ST
EM
Содержание AIRSTAGE V-II
Страница 10: ...1 GENERAL INFORMATION ...
Страница 32: ...2 MODEL SELECTION ...
Страница 207: ...3 OUTDOOR UNITS ...
Страница 251: ...SOUND LEVEL CHECK POINT Microphone 1 m 1 m 03 44 OUTDOOR UNITS OUTDOOR UNITS ...
Страница 265: ...4 INDOOR UNITS ...
Страница 308: ... Unit mm INSTALLATION PLACE 50 or more 90 or more 60 or more 1800 or more 1500 or more 04 43 INDOOR UNITS INDOOR UNITS ...
Страница 310: ... Unit mm INSTALLATION PLACE 60 or more 200 or more 50 or more 1500 or more 2300 or more 04 45 INDOOR UNITS INDOOR UNITS ...
Страница 312: ...4 5 2 CASSETTE TYPE MODELS AUXD18 AUXD24 AUXA30 AUXA36 AUXA45 AUXA54 04 47 INDOOR UNITS INDOOR UNITS ...
Страница 313: ...4 5 3 COMPACT DUCT TYPE MODELS ARXB07 ARXB09 ARXB12 ARXB14 ARXB18 04 48 INDOOR UNITS INDOOR UNITS ...
Страница 314: ...4 5 4 LOW STATIC PRESSURE DUCT TYPE MODEL ARXB24 MODELS ARXB30 ARXB36 04 49 INDOOR UNITS INDOOR UNITS ...
Страница 315: ...MODEL ARXB45 04 50 INDOOR UNITS INDOOR UNITS ...
Страница 316: ...4 5 5 DUCT TYPE MODEL ARXA24 MODELS ARXA30 ARXA36 ARXA45 04 51 INDOOR UNITS INDOOR UNITS ...
Страница 317: ...4 5 6 HIGH STATIC PRESSURE DUCT TYPE MODELS ARXC36 ARXC45 ARXC60 MODELS ARXC72 ARXC90 04 52 INDOOR UNITS INDOOR UNITS ...
Страница 318: ...4 5 7 FLOOR CEILING TYPE MODELS AB A12 AB A14 AB A18 AB A24 04 53 INDOOR UNITS INDOOR UNITS ...
Страница 319: ...4 5 8 CEILING TYPE MODELS AB A30 AB A36 AB A45 AB A54 04 54 INDOOR UNITS INDOOR UNITS ...
Страница 320: ...4 5 9 COMPACT WALL MOUNTED TYPE EEV internal model MODELS AS A07 AS A09 AS A12 AS A14 04 55 INDOOR UNITS INDOOR UNITS ...
Страница 321: ...4 5 10 COMPACT WALL MOUNTED TYPE EEV external model MODELS AS E07 AS E09 AS E12 AS E14 04 56 INDOOR UNITS INDOOR UNITS ...
Страница 322: ...4 5 11 WALL MOUNTED TYPE MODELS AS A18 AS A24 AS A30 04 57 INDOOR UNITS INDOOR UNITS ...
Страница 388: ...5 CONTROL SYSTEM ...
Страница 472: ...6 SYSTEM DESIGN ...
Страница 694: ...7 OPTIONAL PARTS ...