Wiring system outline
3ø 3W 60Hz 208/230V
3ø 3W 60Hz 208/230V
3ø 3W 60Hz 208/230V
Outdoor unit power supply cable
3ø 3W 60Hz 208/230V
Remote controller cable (2 line) non-polar 2 core cable,
seathed cable 22AWG (0.33mm
2)
*Shilded cable might be required in accordance with the regional standard
Remote controller cable (2 line) polar
2 core cable, seathed cable
22 AWG (0.33mm²)
*Shilded cable might be required
in accordance with the regional standard
USB adaptor
(locally purchased)
USB
adaptor
USB
adaptor
USB
adaptor
Central
Remote
Controller
Network
convertor
for
L
ON
W
ORKS
Modbus
convertor
for VRF
Network convertor
Web Monitoring Tool
Internet
or
Public Telephone Line
Transmission line
line is non-polar 2-conductor.
Required in case of follows
Transmission line 1,640 ft (500m) or more
Number of unit 64 or more
Can be connect anywhere
on transmission line
(Locally purchased)
(Locally purchased)
External switch controller cable
Polar 3 core, shielded, 22 AWG (0.33mm²)
Max length 82ft (25m)
Remote controller cable
Polar 3 core, 22 AWG (0.33mm²)
System without remote controller
Together with Touch panel controller, it is
possible to build non remote controller system.
Remote controller line (2 wire)
Maximum 16 units can be controlled
Total wiring length : Max 500m
Remote controller line (3 wire)
Maximum 16 units can be controlled
Total wiring length : Max 1,640 ft (500m)
Touch Panel
Controller
System
Controller
IR receiver unit
Duct type indoor unit
can be controlled with
wireless remote controller.
Service Tool
Multi system
Card key
Single system
Outdoor unit
Indoor unit
(Cassette)
Indoor unit
(Duct)
RB unit
(Single)
RB unit
(Multi)
Touch Panel
Controller
Group Remote
Controller
Wired Remote
Controller
Wired Remote
Controller
Central Remote
Controller
Simple Remote
Controller
Simple Remote
Controller
Simple Remote
Controller
Transmission line
Module link
Remote controller
line (3 wire)
Remote controller
line (2 wire)
Signal line
(single system)
USB cable
Wireless Remote
Controller
External Switch
Controller
IR Receiver unit
(VRF system side)
(Monitoring side)
(Monitoring side)
(Monitoring side)
BACnet Gateway
BACnet
L
ON
W
ORKS
Modbus
L
ON
W
ORKS
®
network
Modbus
®
network
BACnet
network
BACnet Operator
Workstation (B-OWS)
NW1
NW2
NW3
NW4
1ø 60Hz 208/230V
1ø 50/60Hz 220-240V
1ø 50/60Hz 220-240V
1ø 50/60Hz 100 to 240V
1ø 50/60Hz 100 to 240V
1ø 50Hz 230V
1ø 60Hz 208/230V
1ø 50/60Hz 208-240V
1ø 50/60Hz 220-240V
1ø 50/60Hz 220-240V
Disconnect switch might be required in accordance with the regional standard.
Transmission cable
Non polar 2core,
shielded Level4,
22 AWG (0.33mm²)
(Remote /
Monitoring
side)
(Remote /
Monitoring
side)
Wireless LAN adapter
Remotely manage an Air Conditioning
system using all sort of mobile devices
such as Smartphones, and tablets.
Internet
Signal amplifier
4-1. Electrical wiring
- (06-49) -
4. Wiring design
SYSTEM
DESIGN
SYSTEM
DESIGN
Содержание AIRSTAGE J-IIIL
Страница 1: ...DESIGN TECHNICAL MANUAL ...
Страница 3: ...1 GENERAL INFORMATION 2019 11 01 DV_CH01_J3LU061EF_02 ...
Страница 20: ...2 5 Others 01 16 2 Optional parts GENERAL INFORMATION GENERAL INFORMATION ...
Страница 21: ...2 MODEL SELECTION 2019 11 01 DV_CH02_J3LU061EF_02 ...
Страница 94: ...5 1 Stand alone 02 72 5 Heating capacity table Outdoor unit MODEL SELECTION MODEL SELECTION ...
Страница 95: ...3 OUTDOOR UNITS 2019 03 07 DV_CH03_J3LU061EF_01 ...
Страница 113: ...6 2 Model AOU120RLAVL 6 2 Model AOU120RLAVL 03 17 6 Wiring diagrams OUTDOOR UNITS OUTDOOR UNITS ...
Страница 120: ...11 1 Stand alone 03 24 11 Accessories OUTDOOR UNITS OUTDOOR UNITS ...
Страница 121: ...4 INDOOR UNITS 2019 11 01 DV_CH04_J3LU061EF_02 ...
Страница 194: ...5 4 Mini duct type Model ARUL4TLAV1 5 4 Mini duct type 04 70 5 Wiring diagrams INDOOR UNITS INDOOR UNITS ...
Страница 203: ... Models ASUA12TLAV1 and ASUA14TLAV1 5 11 Wall mounted type 04 79 5 Wiring diagrams INDOOR UNITS INDOOR UNITS ...
Страница 205: ... Models ASUA30TLAV2 and ASUA36TLAV2 5 11 Wall mounted type 04 81 5 Wiring diagrams INDOOR UNITS INDOOR UNITS ...
Страница 206: ... Models ASUA7TLAV and ASUA12TLAV 5 11 Wall mounted type 04 82 5 Wiring diagrams INDOOR UNITS INDOOR UNITS ...
Страница 337: ...5 CONTROL SYSTEM 2019 11 01 DV_CH05_VR2E018EF_04 ...
Страница 521: ...6 SYSTEM DESIGN 2019 11 01 DV_CH06_J3LU061EF_02 ...
Страница 599: ...7 FUNCTION SETTINGS 2019 11 01 DV_CH07_J3LU061EF_02 ...
Страница 753: ...8 EXTERNAL INPUT AND OUTPUT 2019 11 01 DV_CH08_J3LU061EF_02 ...
Страница 831: ...9 NOTES 2019 11 01 DV_CH09_J3LU061EF_04 ...
Страница 850: ...4 2 Wiring connection 09 18 4 About connection between series NOTES NOTES ...
Страница 851: ...10 OPTIONAL PARTS 2019 11 01 DV_CH10_VR2E018EF_05 ...