1) Remote controller address setting (for Wall-mounted type only)
NOTES:
• Because this setting is normally done automatically when 2-wire-type wired remote controller is
installed, setting is unnecessary.
• This setting is configurable only by wireless remote controller, but not configurable by Polar 3-
wired remote controller.
Multiple indoor units can be operated by using one wired remote controller.
Set the unit number of each indoor unit.
Function number
Setting value
Setting description
Factory setting
00
00
Unit no. 0
♦
01
Unit no. 1
02
Unit no. 2
03
Unit no. 3
04
Unit no. 4
05
Unit no. 5
06
Unit no. 6
07
Unit no. 7
08
Unit no. 8
09
Unit no. 9
10
Unit no. 10
11
Unit no. 11
12
Unit no. 12
13
Unit no. 13
14
Unit no. 14
15
Unit no. 15
NOTES:
• When connecting Polar 3-wired remote controller, set the remote controller address in the order
of 0, 1, 2, ....., and 15.
• When different type of indoor units (such as wall mounted type and cassette type, cassette type
and duct type, or other combinations) are connected using group control system, some func-
tions may no longer be available.
2) Filter sign
Select appropriate intervals for displaying the filter sign on the indoor unit according to the estimated
amount of dust in the air of the room.
If the indication is not required, select "No indication" (03).
Function number
Setting value
Setting description
Factory setting
11
00
Standard
01
Long interval
02
Short interval
03
No indication
♦
Setting
description
Compact
cassette
Mini duct
Slim duct
Medium static
pressure duct
Wall mounted
Standard
2,500 hours
400 hours
2,500 hours
400 hours
Long interval
4,400 hours
1,000 hours
4,400 hours
1,000 hours
Short interval
1,250 hours
200 hours
1,250 hours
200 hours
- 269 -
14-5. Function details
14. Function settings
4-5 UNIT
MULTI-SPLIT TYPE
4-5 UNIT
MULTI-SPLIT TYPE