5.
Push TEST RUN switch for more than 3 seconds.
MONITOR
POWER
ERROR
/MODE
(GRN) (RED)
A
B
C
D
E
F
POWER/MODE LED will turn on, and test run stops.
14-3. Error code
If an error occurs, the LED lights to inform the relevant location and the code.
When error occurs, the error LED blinks at high speed.
MONITOR
POWER
ERROR
/MODE
(GRN) (RED)
A
B
C
D
E
F
blink
(High speed)
¢
Error location
LEDs A to F of MONITOR light and indicate the location of the error. In the case of an overall
error, LEDs A to F of MONITOR do not light.
Example:
Coil error on indoor unit B
MONITOR
POWER
ERROR
/MODE
(GRN) (RED)
A
B
C
D
E
F
blink
(High speed)