Indoor unit: 22,000 Btu/h
Cooling
Pipe length
m
2.5
5
10
15
20
25
Height difference H (m)
Indoor unit is higher
than outdoor unit *1
15
—
—
—
0.978
0.969
0.953
10
—
—
0.986
0.986
0.977
0.961
5
—
0.992
0.994
0.994
0.984
0.968
2.5
0.996
0.996
0.998
0.998
0.988
0.972
0
1.000
1.000
1.002
1.002
0.992
0.976
Indoor unit is lower
than outdoor unit *2
-2.5
1.000
1.000
1.002
1.002
0.992
0.976
-5
—
1.000
1.002
1.002
0.992
0.976
-10
—
—
1.002
1.002
0.992
0.976
-15
—
—
—
1.002
0.992
0.976
Heating
Pipe length
m
2.5
5
10
15
20
25
Height difference H (m)
Indoor unit is higher
than outdoor unit *1
15
—
—
—
0.964
0.939
0.913
10
—
—
0.988
0.964
0.939
0.913
5
—
1.000
0.988
0.964
0.939
0.913
2.5
1.000
1.000
0.988
0.964
0.939
0.913
0
1.000
1.000
0.988
0.964
0.939
0.913
Indoor unit is lower
than outdoor unit *2
-2.5
0.998
0.997
0.986
0.962
0.937
0.911
-5
—
0.995
0.983
0.959
0.934
0.909
-10
—
—
0.978
0.954
0.929
0.904
-15
—
—
—
0.949
0.925
0.899
¢
Indoor unit: 24,000 Btu/h
Cooling
Pipe length
m
2.5
5
10
15
20
25
Height difference H (m)
Indoor unit is higher
than outdoor unit *1
15
—
—
—
0.978
0.969
0.953
10
—
—
0.986
0.986
0.977
0.961
5
—
0.992
0.994
0.994
0.984
0.968
2.5
0.996
0.996
0.998
0.998
0.988
0.972
0
1.000
1.000
1.002
1.002
0.992
0.976
Indoor unit is lower
than outdoor unit *2
-2.5
1.000
1.000
1.002
1.002
0.992
0.976
-5
—
1.000
1.002
1.002
0.992
0.976
-10
—
—
1.002
1.002
0.992
0.976
-15
—
—
—
1.002
0.992
0.976
Heating
Pipe length
m
2.5
5
10
15
20
25
Height difference H (m)
Indoor unit is higher
than outdoor unit *1
15
—
—
—
0.964
0.939
0.913
10
—
—
0.988
0.964
0.939
0.913
5
—
1.000
0.988
0.964
0.939
0.913
2.5
1.000
1.000
0.988
0.964
0.939
0.913
0
1.000
1.000
0.988
0.964
0.939
0.913
Indoor unit is lower
than outdoor unit *2
-2.5
0.998
0.997
0.986
0.962
0.937
0.911
-5
—
0.995
0.983
0.959
0.934
0.909
-10
—
—
0.978
0.954
0.929
0.904
-15
—
—
—
0.949
0.925
0.899
- 429 -
7-1. Model: AOYG36KBTA5
7. Capacity compensation rate for pipe length and height difference
OUTDOOR UNIT
AOYG36KBTA5
OUTDOOR UNIT
AOYG36KBTA5