¢
Combination of external input and output
By combining the function setting of the indoor unit, you can select various combinations of func-
tions.
Combination examples of external input and output are as follows:
Mode
Function setting
External input
External output
Terminal
CN47
0
60—00
Operation/Stop
1—8
60—01 to 60—08
(Setting prohibited)
9
60—09
Operation/Stop
Error status
10
60—10
Operation/Stop
Indoor unit fan operation status
11
60—11
Operation/Stop
External heater output
NOTE:
Input of Operation/Stop depends on the setting of function setting 46.
• 00: Operation/Stop mode 1 (R.C. enabled)
• 01: (Setting prohibited)
• 02: Forced stop
• 03: Operation/Stop mode 2 (R.C. disabled)
Input signal type
• Indoor unit
Input signal type is only "Edge".
Edge
- 152 -
11-1. Compact cassette type, Mini duct type, Slim duct type, and Medium static pressure
duct type
11. External input and output
4-5 UNIT
MULTI-SPLIT TYPE
4-5 UNIT
MULTI-SPLIT TYPE