Description of display
LED lamp
Function or operation method
(1) POWER/MODE
Green
• Turns on when the power supply is ON (Including
when error occurs).
• Indicate the MODE by the number of flashes when
the installation function is active.
(2) ERROR
Red
Flashes at high-speed when there is an error.
(3) MONITOR
A
Red
• Displays the location and contents of errors when
there is an error. (Refer to Chapter 14-3.
• Displays when check run is activated. (Refer to
B
Red
C
Red
D
Red
E
Red
F
Red
Switch
Function or operation method
Factory setting
SW1
Push
• For the test run start and stop.
• For the pump down start and stop.
—
SW2
Push
• For when check run function is activated.
• For displaying the check run.
• For resetting the Automatic wiring correction memory.
—
SET1-1
DIP
For selecting cooling or heating during test operation.
OFF
SET1-2
DIP
For switching SW1 operation.
OFF
SET1-3
DIP
(Prohibited)
OFF (Do not change)
SET1-4
DIP
For outdoor unit low noise operation function.
OFF
SET2-1
DIP
For selecting outdoor unit low noise operation function.
OFF
SET2-2
DIP
(Prohibited)
OFF (Do not change)
SET2-3
DIP
Changing the current limit
OFF
SET2-4
DIP
Be sure to disconnect the power supply or turn off the breaker before changing the DIP switch