![FujiFilm PXG4 Скачать руководство пользователя страница 51](http://html1.mh-extra.com/html/fujifilm/pxg4/pxg4_operation-manuals_2342483051.webp)
– 50 –
5
Chapter
Anti-reset Windup
to
Sets the anti-reset windup. Up to seven types of anti-
reset windup (palettes 1 to 7) can be recorded. Recorded
anti-rest windup can be recalled from selected PID
number ("
PPP
PLLLLnnnn1111
") in the operation menu.
• Range: 0.0% to 100.0%
Setting the Anti-reset Windup
The following steps explain how to set the anti-reset windup
by using 200°C as an example.
Refer to
See "Anti-reset Windup" (p. 36) for more information on the anti-
reset windup.
1
Press and hold the
key to display the setup
mode channel menu ("
ooo
oPPPPEEEE CCCChhhh 1111
") then use the
keys to display PLT ("
PPP
PLLLLTTTT CCCChhhh 3333
").
Refer to
See p. 46 in this chapter for information on how to display
the channel menu.
2
Press and hold the
key to display the SV
parameter ("
SSS
Svvvv 1111
"), then use the
keys to
display Ar1 ("
AAA
Arrrr1111
").
3
Press the
key, then use the
keys to
display "200.0" when the bottom part of the
display begins to blink.
Anti-reset windup is set to 200.0°C.
4
Press the
key to confirm the setting.
5
Press the
key to return to the operation mode
PV/SV display.
Normal/Reverse Setting
to
The following sets the normal/reverse setting. Up to
seven types of normal/reverse settings (palettes 1 - 7)
can be recorded. Recorded normal/reverse settings can
be recalled from selected PID number ("
PPP
PLLLLnnnn1111
") in the
operation menu.
Setting the Normal/Reverse Setting
The following steps explain how to set normal/reverse settings
by using heat (reverse) / cool (normal) as an example.
Range
Control Operation
rv--
(heat (reverse) / cool (none))
no--
(heat (normal) / cool (none))
rvno
(heat (reverse) / cool (normal))
norv
(heat (normal) / cool (reverse))
rvrv
(heat (reverse) / cool (reverse))
nono
(heat (normal) / cool (normal))
Refer to
See "Normal/Reverse Settings" (p. 37) for more information on
normal/reverse settings,
1
Press and hold the
key to display the setup
mode channel menu ("
ooo
oPPPPEEEE CCCChhhh 1111
") then use the
keys to display PLT ("
PPP
PLLLLTTTT CCCChhhh 3333
").
Refer to
See p. 46 in this chapter for information on how to display
the channel menu.
2
Press and hold the
key to display the SV
parameter ("
SSS
Svvvv 1111
"), then use the
keys to
display rEv1 ("
rrr
rEEEEvvvv1111
").
3
Press the
key, then use the
keys to
select "rvno" when the bottom part of the display
begins to blink.
The normal/reverse setting is now set to heat
(reverse) / cool (normal).
4
Press the
key to confirm the setting.
5
Press the
key to return to the operation mode
PV/SV display.
Point
For safety reasons, make sure to turn off power to the
system when switching the normal/reverse operations
while using the PID selection function. (Do not switch
between normal and reverse operation while controlling.)
Содержание PXG4
Страница 1: ...c...
Страница 10: ...9 1 Chapter Chapter 1 Part Names and Functions Part Names and Functions 10...
Страница 21: ...20 MEMO 2 Chapter...
Страница 43: ...42 MEMO 4 Chapter...
Страница 53: ...52 MEMO 5 Chapter...
Страница 71: ...70 MEMO 7 Chapter...
Страница 89: ...88 MEMO 8 Chapter...
Страница 106: ...105 9 Chapter Behavior when control is lost Limit Cycle PV SV Time tuning MV control lost 100...
Страница 119: ...118 MEMO 10 Chapter...
Страница 125: ...124 MEMO 11 Chapter...
Страница 131: ...130 MEMO 12 Chapter...
Страница 132: ...131 13 Chapter Chapter 13 Password Setup Ch11 Overview of Password Setup Ch11 132 Passwords 1 to 3 132...
Страница 141: ...140 MEMO 14 Chapter...
Страница 151: ...150 MEMO 15 Chapter...
Страница 152: ...151 16 Chapter Chapter 16 Troubleshooting Troubleshooting 152...
Страница 154: ...153 17 Chapter Chapter 17 Appendix Delay Start Function 154 Return to Factory Default Setting Function 155...
Страница 157: ...156 MEMO 17 Chapter...