5. Inspection
48
FinePix F601 Zoom (U/E/EG) SERVICE MANUAL
Item
Delete mode
check
Mode
Delete
Preparations for adjustment
and measurement
(1) Select Format from menu
and press OK button.
(2) Press OK button again.
Adjustment and measurement
method
(1) “Delete All Frames OK?” dis-
played.
(2) Playback screen disappears.
Measuring
instrument
LCD monitor
Recorded
smart media
Measurement
point
<Step 10>
<Step 11>
Item
Battery low
check
Mode
Auto Pho-
tography
LCD ON
Preparations for adjustment
and measurement
(1) Connect NP-60 battery jig.
(2) Set to end voltage.
Adjustment and measurement
method
(1) See Battery Adjustment for
connections.
(2) Set voltage to 3.13±0.01V.
Lens retracts and camera
power is switched OFF.
Measuring
instrument
Battery jig
Stabilized
power sup-
ply
Measurement
point
<Step 12>
Item
Current con-
sumption
check
Mode
Auto Pho-
tography
LCD ON
Preparations for adjustment
and measurement
(1) Connect power supply
cable jig.
(2) Set voltage.
(3) Set mode dial to Camera
mode, and switch camera
power ON.
(4) Check current consump-
tion in viewfinder.
Adjustment and measurement
method
(1) See DC jack adjustment for
connections.
(4) Maximum 550[mA].
Measuring
instrument
Power sup-
ply cable jig
Ammeter
Measurement
point
<Step 13>
Item
Leakage cur-
rent check
Mode
Power OFF
Preparations for adjustment
and measurement
(1) Switch power OFF.
Adjustment and measurement
method
(1) Leakage current maximum of
1mA.
Measuring
instrument
Power sup-
ply cable jig
Ammeter
Measurement
point
LCD monitor
<Step 14>
Item
Settings at
shipment
Settings at
packaging
upgrade
Mode
Auto Pho-
tography
Preparations for adjustment
and measurement
(1) Run Full Reset from Set-
tings menu to return to
defaults.
(2) Defaults are as follows.
Photography image dis-
play:
OFF
Auto power save:
2MIN
USB setting: Card reader
Beep:
LOW
LCD monitor: ON
Quality:
NORMAL
Date:
Not set
(3) Inspection battery/inspec-
tion SSFDC not in camera.
(4) No contamination on LCD/
EVF.
(5) Clean exterior of camera.
(1) No damage or contamina-
tion on exterior of camera
in STEP14 (5).
(2) Upgrade packaging in
accordance with parts list
details.
Adjustment and measurement
method
(1) The camera may be set to the
mode set at shipment from the
factory with the following pro-
cedure.
1. Connect the camera to the
computer with the USB cable.
2. Open the battery cover.
3. Switch power supply ON (AC
adapter may also be used).
4. Switch power ON while
pressing the shutter button.
5. Switch the power supply OFF
with the camera POWER
button.
Measuring
instrument
Measurement
point