47
5. Inspection
FinePix F601 Zoom (U/E/EG) SERVICE MANUAL
Item
Check movie
and audio
playback.
Mode
Playback
mode
LCD ON
Preparations for adjustment
and measurement
(1) Set to Playback mode.
(2) Press 8-direction button
and select Movie record-
ing mode.
(3) Press 8-direction button
to playback movie.
Adjustment and measurement
method
(1) LCD monitor displays playback
operation (lens retracted after
approximately six seconds).
(2) LCD monitor and mode LED
display movie playback opera-
tion.
(3) Movie played back on LCD
monitor.
Audio played back from cam-
era speaker.
Measuring
instrument
Camera
speaker
LCD monitor
Measurement
point
<Step 6>
<Step 7>
Item
Flash
Photograph
check image
Mode
M mode
LCD ON
Preparations for adjustment
and measurement
(1) Set to Manual Photogra-
phy mode.
(2) Set White Balance mode
to Auto mode.
(3) Set to ISO sensitivity 200.
(4) Set aperture to F2.8.
(5) Set number of recorded
pixels to 640x480 (others
to defaults).
(6) Set as for flash adjust-
ment.
(7) Take photograph.
Adjustment and measurement
method
(6) See Setup for Flash Adjust-
ment diagram.
(7) Recorded on smart media.
Measuring
instrument
Gray chart
Measurement
point
<Step 8>
Item
Y level/WB
Photograph
check image
Mode
M mode
LCD ON
Preparations for adjustment
and measurement
(1) Set to Program Photogra-
phy mode.
(2) Set White Balance mode
to Lamp mode.
(3) Set flash to OFF.
(4) Set number of recorded
pixels to 640x480.
(5) Set to Manual Focus mode
(others to defaults).
(6) Set camera as for CAM
adjustment.
(7) Take photograph
→
with-
out all white filter.
Adjustment and measurement
method
(6) See Setup for Camera Adjust-
ment diagram.
(7) Recorded on smart media.
Measuring
instrument
Pattern box
Measurement
point
<Step 9>
Item
Check play-
back image
(flash/WB Y
level)
Mode
Playback
mode
Preparations for adjustment
and measurement
(1) Place the smart media
which contains the photo-
graph recorded in STEP7
and 8 in image check cam-
era.
(2) Set image check camera to
Playback mode, and play-
back recorded image.
(3) Playback flash check
photographic image.
(4) Playback Y level/WB check
photographic image.
(5) Playback Y level/WB check
photographic image.
Adjustment and measurement
method
(3) Playback image within 48±10
[IRE] on waveform monitor dis-
play.
(4) Playback image within 72 to 97
[IRE] on waveform monitor dis-
play.
(5) Center of luminescent spot
located within radius of 10% of
circle with center at X=-1%, Y=
-8.5% on vector scope.
Measuring
instrument
Check camera
Waveform
monitor
TV monitor
Measurement
point
(3) Waveform monitor
(4) Waveform monitor
8.5%
1%
10%
WB specification requirements
(5) Vector scope
Center of luminescent