Installation Procedure Checklist for H-20, HS-20,
Traffic-Rated Tank and No Support Columns
Note:
Please consult Installation Manual for detailed instructions.
Unloading Instructions:
Upon delivery, inspect FujiClean tank, both outside and inside for possible damage incurred during
transport. If you find damage, or have a question, please contact your distributor immediately.
Step 1: Prepare excavation following this instruction and drawing plan. Importance: Distance
between ground level and adapter ring is 24 inches.
Step 2: Prepare 4”- 6” bed of stone (1/8”).
Step 3: Set pre-cast concrete or pour concrete base. In case of Traffic-Rated Tank, install the
concrete box accurately.
Step 4: Use 4-point lifting lugs. Carefully lower and set tank. Level to within 1/8-inch per 2-ft..
Step 5: Fill tank with fresh water to the low water line in ALL 3 chambers. Re-check that tank is
level to 1/8-inch per 2-ft., (fore and aft as well as side to side) and then fill tank with fresh water to
the low water line (marked inside tank). Start 24-hour water tightness test. (Please contact your
distributor or FujiClean USA if water level has dropped after 24 hours).
Step 6: Backfill about ¾ way up tank in layered, compacted 6” lifts using peastone or equivalent
material that form-fits into tank corrugations. Install inlet/outlet lines using 5x4 reducing bushing if
necessary.
Step 7: 3/4” air line pipe can connect to the tank directly. Connect 3/4” or 1” conduit that is chosen
by distance in prepared trench (min. 6” deep) to location of air pump. For CE14, CE21, CEN14, locate
air pump within 33’ for ¾” or 1” air line or 100’ for 1” air line. For CE30 and CEN21 use 1” air line.
Connect with no more than 5 elbows on each models.
Step 8: Locating and Installing Air Pump/ Control Panel.
Air Pump shall be:
in as close proximity to control panel as possible
on a solid (e.g. concrete) pad to minimize vibrations
in a location above water level
away from grease exhaust fans.
away from bedroom windows and other locations where operational sounds (although
minimal) may be a nuisance
In a location that allows unencumbered access for inspection and maintenance activity
with proper electrical grounding
with wiring and electrical connections made by a licensed electrician.
with no objects on top of electrical cord.
in a well-ventilated space out of direct sunlight and protected from elements such as
direct rain or snowfall.