Step 8: Locating and Installing Air Pump/Control
Panel.
Air Pump shall be:
in as close proximity to control panel as possible
on a solid (e.g. concrete) pad to minimize
vibrations
in a location above water level
away from grease exhaust fans
away from bedroom windows and other locations
where operational sounds (although minimal) may
be a nuisance
in a location that allows unencumbered access for
inspection and maintenance activity
with proper electrical grounding
with wiring and electrical connections made by a
licensed electrician
with no objects on top of electrical cord
in a well-ventilated space out of direct sunlight
and protected from elements
Alarm/Control Panel shall be:
in a well ventilated area as dry and protected from
elements as much as possible
in as close of proximity to FujiMAC air pump as
possible
wired by qualified electrician
in a location that allows unencumbered access for
inspection and maintenance activity
Step 7 continued: Set risers on the tank as
necessary. Maximum riser height is 24-
inches.