Step 9: For cold climate installations, please install insulated riser covers and cover upper half of
treatment unit with min. R-8 value insulating material (i.e. foam board).
Step 10: Connect float switch electrical cord through a male adaptor (caulked watertight
to prevent septic gas leakage) or watertight fitting. An interior connection to direct burial
cable is also an acceptable option.
For connection of float switch cord to alarm panel, drill
hole in riser and use male fitting and electrical conduit.
Plug fitting with approved sealant to assure water-tight
seal and to prevent septic gas transmission into control
panel.
Caulk around cable in conduit to block septic air flow to control panel.