![Fuji Electric 6MBP15XSD060-50 Скачать руководство пользователя страница 56](http://html1.mh-extra.com/html/fuji-electric/6mbp15xsd060-50/6mbp15xsd060-50_applications-manual_2341763056.webp)
7-3
Fuji Electric Co., Ltd.
MT6M12343 Rev.1.0
Dec.-2016
Chapter 7 Cautions
2. Precautions on storage
•
It is recommended to storage the IPM under the temperature of 5 to 35
℃
and relative humidity of 45 to 75%. If the storage
area is very dry, a humidifier may be required. In such a case, use only deionized water or boiled water, since the chlorine
in tap water may corrode the leads.
•
The IPM may not be subjected to rapid changes in temperature to avoid condensation on the surface of the IPM. Therefore
store the IPM in a place where the temperature is steady.
•
The IPM should not be stored on top of each other, since this may cause excessive external force on the case. When the
IPM stored in packing box, to avoid deformation of the box, please load the box correctly.
•
The IPM should be stored with the lead terminals remaining unprocessed. Rust may cause presoldered connections to fail
during later processing.
•
The IPM should be stored in antistatic containers or shipping bags.
•
Under the above storage condition, the shelf life is one year.