Fuji Electric Co., Ltd.
3-20
MT6M12343 Rev.1.0
Dec.-2016
Chapter 3
Detail of Signal Input/Output Terminals
Fig.3-25 Operation sequence of TEMP terminal at the LVIC startup and shut down conditions
t
1
-
t
2
: TEMP function is activated when
V
CCL
exceeds
V
CCL(ON)
. If
V
CCL
is less than
V
CCL(ON)
, the TEMP
terminal voltage is the same as the clamp voltage.
t
2
-
t
3
: TEMP terminal voltage rises to the voltage determined by LVIC temperature. In case the
temperature is clamping operation, the TEMP terminal voltage is the clamp voltage even though
V
CCL
is above
V
CCL(ON)
.
t
3
-
t
4
: TEMP function is reset when
V
CCL
falls below
V
CCL(OFF)
. TEMP terminal voltage is the same as
the clamp voltage.
V
CCL
increasing
V
CCL
decreasing
V
CCL
voltage
VFO
terminal
voltage
TEMP
terminal
voltage
t
1
t
2
V
CCL(ON)
V
CCL(OFF)
t
3
t
4