![Frymaster BIELA14-T Series Скачать руководство пользователя страница 77](http://html.mh-extra.com/html/frymaster/biela14-t-series/biela14-t-series_installation-operation-and-maintenance-manual_2340403077.webp)
7-8
Code
ERROR MESSAGE
EXPLANATION
E53
CAN BUS ERROR - CALL SERVICE
Communications are lost between boards.
E54
USB ERROR
USB connection lost during an update.
E55
SYSTEM INTERFACE BOARD 2 MISSING - CALL SERVICE
SIB board 2 connection lost or board failure.
E61
MISCONFIGURED ENERGY TYPE
The fryer is configured for the incorrect energy
type.
E62
VAT NOT HEATING – CHECK ENERGY SOURCE – XXXF
OR XXXC
The vat is not heating properly.
E63
RATE OF RISE
Rate of rise error occurred during a recovery test.
E64
FILTRATION INTERFACE BOARD FAILURE - FILTRATION
AND TOP OFF DISABLED - CALL SERVICE
Filtration Interface Board connections lost or
board failure.
E65
CLEAN OIB SENSOR – XXX F OR XXX C - CALL SERVICE
Gas -The oil is back sensor does not detect oil.
Clean oil sensor (see section 6.6.2).
E66
DRAIN VALVE OPEN – XXXF OR XXXC
Drain valve is opened during cooking.
E67
SYSTEM INTERFACE BOARD NOT CONFIGURED - CALL
SERVICE
Controller is turned on when the SIB board is not
configured.
E68
OIB FUSE TRIPPED – CALL SERVICE
The VIB board OIB fuse has tripped and didn’t
reset.
E69
RECIPES NOT AVAILABLE – CALL SERVICE
The controller has not been programmed with
product recipes. Replace controller with factory
programmed controller.
E70
OQS TEMP HIGH
Oil temperature is too high for a valid OQS
reading. Filter at a temperature between 300ºF
(149ºC) and 375ºF (191ºC).
E71
OQS TEMP LOW
Oil temperature is too low for a valid OQS reading.
Filter at a temperature between 300ºF (149ºC) and
375ºF (191ºC).
E72
TPM RANGE LOW
The TPM is too low for a valid OQS reading. This
may also be seen with fresh new oil. The incorrect
oil type may be selected in the setup menu. The
sensor may not be calibrated for the oil type. See
oil type chart in instruction document 8197316. If
issue continues contact a FAS.
E73
TPM RANGE HIGH
The TPM reading is too high for a valid OQS
reading. Dispose the oil.
E74
OQS ERROR
The OQS has an internal error. If issue continues
contact a FAS.
E75
OQS AIR ERROR
The OQS is detecting air in the oil. Check the O-
rings and check/tighten prescreen filter to ensure
no air is entering the OQS sensor. If issue
continues contact a FAS.
E76
OQS ERROR
The OQS sensor has a communication error. Check
connections to the OQS sensor. Power cycle the
entire fryer battery. If issue continues contact a
FAS.