7-6
7.3.2 Filter Busy
When
FILTER BUSY
is displayed the filter interface board is waiting on another vat to be filtered or waiting on
another function to finish. Wait 15 minutes to see if problem is corrected. If not, call your local FAS.
7.4 Troubleshooting Auto Top Off Issues
PROBLEM
PROBABLE CAUSES
CORRECTIVE ACTION
Frypots top off cold.
Incorrect setpoint.
Ensure setpoint is correct.
One vat doesn’t top off.
A.
Filter error exists.
B.
Service required error exists
C.
Solenoid, pump, pin issue, RTD or ATO
issue.
A.
Clear filter error properly. If problem
persists call your FAS for assistance.
B.
Call your FAS for assistance.
C.
Call your FAS for assistance.
Frypots won’t top off.
A.
Fryer temperature too low.
B.
Oil is too cold.
C.
Yellow top off oil indicator illuminated
D.
Service required error exists
E.
Melting unit switch is off (only on solid
shortening units)
F.
Blown fuse.
A.
Fryer temperature must be at
setpoint.
B.
Ensure that the oil in the top off
reservoir is above 70°F (21°C).
C.
Ensure the top off reservoir is not
out of oil. Replace top off reservoir
or fill from bulk and reset top off
system.
If problem persists call your FAS for
assistance.
D.
Call your FAS for assistance.
E.
Ensure the switch on the melting unit
is in the ON position.
F.
Check the fuse on the left of the ATO
box. If using a solid shortening
melting unit, check the fuse below
the melting unit switch.
7.5
Troubleshooting Bulk Oil System Problems
PROBLEM
PROBABLE CAUSES
CORRECTIVE ACTION
Top off reservoir
won’t fill.
A.
Incorrect setup procedure.
B.
Another function is in process.
C.
Dispose valve not completely closed.
D.
Bulk oil tank is empty.
E.
Solenoid, pump or switch issue.
A.
Power cycle fryer by disconnecting and
reconnecting 5-pin bulk oil control power
cord on rear of fryer.
B.
If a filtration or any other filter menu
function is in process or FILTER NOW?
YES/NO, CONFIRM YES/NO, or SKIM VAT are
displayed, wait until the process is
complete and try again.
C.
Ensure the dispose valve handle is pushed
fully closed.
D. Call your bulk oil provider.
E.
Call you FAS for assistance.
Top off reservoir
or vat filling slow.
A.
Pump or line issues beyond the scope
of operator troubleshooting.
A.
Contact your bulk oil provider.