4-27
4.14.3 Life Statistics
The life statistics function is used to view the commission date of the fryer which is automatically set once the fryer
has completed 25 cooks, the serial number of the controller, the total time the fryer has operated in hours and the
total heat cycle count of the fryer (the amount of times the controller has turned the heat on/off).
DISPLAY
ACTION
1.
Press the Information button.
2.
Press the Life Stats button.
1.
COMMISSION DATE
2.
UNIT SERIAL NUMBER
3.
CONTROLLER SERIAL NUMBER
4.
TOTAL ON TIME (HOURS)
5.
TOTAL HEAT CYCLE COUNT
3.
Press the back button to return to
menu or the home button to exit.
4.14.4 Usage Statistics
The usage statistics displays total cook cycles per vat, number of cook cycles per vat, number of cook cycles exited
prior to completion, the number of hours the vat(s) have been on and the date of last usage reset.
DISPLAY
ACTION
1.
Press the Information button.
2.
Press the Usage Stats button.
1.
USAGE START DATE
2.
TOTAL NUMBER OF COOK CYCLES
3.
TOTAL NUMBER OF QUIT COOK CYCLES
4.
TOTAL VAT ON TIME (HOURS)
3.
Press the back button to return
to menu or the home button to
exit.
4.14.5 Recovery Time
Recovery is used to determine if the fryer is operating correctly. Recovery is the time required for the fryer to raise
the temperature of the oil 50°F (28°C) between 250°F (121°C) and 300°F (149°C). Maximum recovery time should
not exceed 1:40 for electric or 3:15 for gas.
DISPLAY
ACTION
1.
Press the Information button.
2.
Press the Recovery button. The time is displayed in
minutes and seconds.
1.
LAST RECOVERY TIME
3.
Press the back button to return to menu or the home
button to exit.