2.2 Permitted Uses
The Froling bunker filling system is solely designed for transporting fuels into suitable
store spaces. Only use fuels specified in the "Permitted fuels" section.
The unit should only be operated when it is in full working order. It must be operated in
accordance with the instructions, observing safety precautions, and you should ensure
you are aware of the potential hazards. The inspection and cleaning intervals in the
operating instructions must be observed. Ensure that any faults which might impair
safety are rectified immediately.
The manufacturer or supplier is not liable for any damage resulting from non-permitted
uses.
Only original spare parts or specific alternative spare parts authorised by the
manufacturer may be used. Any kind of change or modification made to the product
will invalidate its manufacturer’s CE conformity. In such cases, the product will need to
undergo new hazard evaluation procedures by the operator. The operator will then be
fully responsible for the declaration of conformity according to the valid guideline(s) for
the product and will need to attach the new CE label to the device. This person will
then assume all of the rights and responsibilities of a manufacturer.
2.2.1 Permitted fuels
Wood chips
Criterion
Designation as per
Description acc. to
ÖNORM M 7133
ÖNORM M 7133
EN ISO 17225
Water content
W20
M20
air-dried
W30
M30
suitable for storage
W35
M35
limited suitability for
storage
Size
G30
P16S
Fine wood chip
G50
P31S
Medium-sized wood
chip
EU:
Fuel acc. to EN ISO 17225 - Part 4: Wood chips class A1 / P16S-P31S
Additional for
Germany:
Fuel class 4 (§3 of the First Federal Emissions Protection Ordinance
(BimSchV) - applicable version)
Note on standards
2
Safety
Permitted Uses
8
Froling GesmbH | A-4710 Grieskirchen, Industriestraße 12 | www.froeling.com