4.6 Install Bunker Filling System
CAUTION
The suitability of the fasteners supplied (e.g. heavy duty anchor) for the
respective attachment basis must be checked by the assembly staff and operator.
If the fasteners supplied are not suitable, then responsibility for selecting the
fasteners lies with the assembly staff.
4.6.1 Install ejection head
Ø 14 mm
❒ Position the wall duct (optional) in the centre of the wall opening
❒ Drill into the outside wall at the position planned for mounting of the external cover
plate
❒ Mount wall duct on wall
➥ There must be holes for installing the filling level sensors on the bottom flap
❒ Position ejection head at wall duct with suitable lifting equipment
❒ Bolt ejection head to wall duct
❒ Attach the sensor brackets with filling level sensors to the flap
If no wall duct is used:
❒ Install the sensor brackets with filling level sensors below the wall opening
➥ Use suitable assembly material
➥ Filling level sensors must not impair the trajectory of the wood chips
Assembly
4
Install Bunker Filling System
Installation- and Operating Intructions BFSV / BFSU | M1420116_en