4.4 Installation variants - BFSV
4.4.1 All components in external area
Depending on the thickness of the wall it should be borne in mind that a wall duct (300
mm / 600 mm) is necessary for mounting the ejection head. When using a wall duct,
the ejection head is directly mounted in place, and no other fixing brackets are
necessary. The filling level sensors are also mounted on the wall duct in this case.
4.4.2 Bulk chute and vertical screw outside
The ejection head is equipped as standard with an explosion-protected drive, which
means that it can be located in the fuel store without consulting the manufacturer. If an
extended discharge shaft is used for bridging the outside wall, the ejection head is
secured to the inside wall of the fuel store with a bracket.
4
Assembly
Installation variants - BFSV
30
Froling GesmbH | A-4710 Grieskirchen, Industriestraße 12 | www.froeling.com