Wire Replacement I/O (900 MHz): User Manual and Reference Guide
UL Notifications
Models FGRIO-M, FGRIO-S, FGR2-IOS-C-U, FGR2-IOS-CE-U and FGR2-IO-IOE are suitable for use in Class I,
Division 2, Groups A, B, C, and D or non-hazardous locations only. Do not connect or disconnect any connectors
while the circuit is live unless the area is known to be non-hazardous.
Warning! EXPLOSION HAZARD
- Substitution of components may impair suitability for Class1,
Division2.
Warning! DO NOT REMOVE
or insert the diagnostics cable while the circuit is live unless the area is
known to be free of ignition concentrations or flammable gases and vapors.
l
Input voltage for the FGR2-IOS-C-U, FGR2-IOS-CE-U, FGR2-IO-IOE, is +6.0 to +30.0 VDC.\
l
Input voltage for the FGRIO-S is +6.0 to +20.0 VDC.
l
Input voltage for the FGRIO-M is +7.5 to +30.0 VDC.
l
Input voltage for the I2-IOM-U is +6.0 to +30.0 VDC.
l
Input voltage for the I2-IOS-C-U is +6.0 to +30.0 VDC.
Important!
:
Input power shall be derived from a single Class 2 power source.
FCC Notifications
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: 1) This
device may not cause harmful interference and 2) this device must accept any interference received, including
interference that may cause undesired operation.
The content of this guide covers FreeWave Technologies, Inc. models sold under FCC ID: KNY-6231812519
(FGR models) and KNY-42182112519 (FGR2 models).
All models sold under the FCC ID(s) listed above must be installed professionally and are only approved for use
when installed in devices produced by FreeWave Technologies or third party OEMs with the express written
approval of FreeWave Technologies, Inc. Changes or modifications should not be made to the device.
Warning!
The FGR2-IOS-C-U, FGR2-IOS-CE-U, FGRIO-M, and FGR2-IO-IOE models have a
maximum transmitted output power of 1 W. The antennas used must provide a separation distance of
at least 23 cm from all persons and must not be co-located or operate in conjunction with any other
antenna or transmitter.
Warning!
The FGRIO-S model has a maximum transmitted output power of 100 mW. The antennas
used must provide a separation distance of at least 23 cm from all persons and must not be co-
located or operate in conjunction with any other antenna or transmitter.
FCC NEMA Installation and Label
Where applicable, the models described in this guide must be installed in a NEMA enclosure. When any
FreeWave Technologies, Inc. module is placed inside an enclosure, a label must be placed on the outside of the
LUM0008AG Rev Sep-2015
Page 3 of 131
This document is the property of FreeWave Technologies, Inc. and contains proprietary information owned by
FreeWave®. This document cannot be reproduced in whole or in part by any means without written permission from
FreeWave Technologies, Inc.
Содержание FGR2-IO-IOE
Страница 131: ......