7
Controller Module (CM)
Power Supply Module (PS)
Non-IS
Modules (red)
IS Modules (blue)
Isolation Barrier
(TS-5000 evo
front view with cover removed)
TM
Non-intrinsically safe module wiring
WARNING
: Always lock out and tag electrical circuit breakers while installing or servicing
this equipment and any related equipment. A potentially lethal electrical shock hazard and the
possibility of an explosion or fire from a spark can result if the electrical circuit breakers are
accidentally turned on during installation or servicing.
IMPORTANT
: Non-intrinsically safe wiring cannot be run in the same conduit as intrinsically safe
wiring. Non-IS modules can be identified by their red faceplates and should always be installed to
the left of the moveable isolation barrier.
Controller module (CM)
The Controller Module (CM) is a non-intrinsically safe module that acts like the brain of your ATG.
The CM handles all of the communication between the modules and then sends that information
to your output devices. You can use the optional touch screen LCD or external printer (depending
on model and configuration) as output devices to communicate with your system. The CM links
to the status lights on the front of the ATG and the LCD via a flexible cable connector.
Flexible cable connector
The flexible cable is installed at the factory and is just long enough to allow the door to fully
open. It is protected from high power wiring by the metal shroud attached to the CM. The cable
should not be deformed, but should rather be freely folded back into the shroud so that it does
not get pinched when the door is closed. If the flexible cable does become detached though, it
can easily be reattached.
To reattach the flexible cable connector, identify the two sides of each end: there are metal bands
on one side and no metals bands on the other. It hooks into the CM by inserting one end of the
ribbon into the LCD connector with it’s metal bands facing to the left so that a metal-to-metal
connection is made with the LCD connector’s pins.