SubDrive/MonoDrive Connect
15
Fuse/Circuit Breaker and Wire Sizing
The Listed fuse/Listed circuit breaker size and maximum allowable wire lengths for
connection to the SubDrive/MonoDrive are given in the following tables:
Model Family
Listed Fuse /
Listed Circuit
Breaker Amps
Nominal
Input
Voltage
AWG Copper Wire Sizes, 167 °F (75 °C) Insulation Unless Otherwise Noted
14
12
10
8
6
4
3
2
1
1/0
2/0
MonoDrive C
15
208
80
125
205
315
500
790
980
1290
1635
-
-
15
230
95
150
250
385
615
970
1200
1580
2000
-
-
SubDrive15 C
15
208
70
110
185
280
450
710
880
1160
1465
-
-
15
230
85
135
225
345
550
865
1075
1415
1795
-
-
MonoDriveXT C
20
208
-
85
140
220
345
550
680
895
1135
-
-
20
230
-
105
175
265
425
670
835
1095
1390
-
-
SubDrive20 C
20
208
-
-
115
180
285
450
555
730
925
-
-
20
230
-
85
140
220
345
550
680
895
1130
-
-
SubDrive30 C
25
208
-
-
95
145
235
370
460
605
765
-
-
25
230
-
-
115
180
285
455
560
740
935
-
-
SubDrive50 C
40
208
-
-
-
-
150
235
295
385
490
610
735
40
230
-
-
-
115
185
290
360
470
600
745
895
Table 1: Circuit Breaker Sizing and Maximum Input Cable Lengths (in Feet)
Based on a 3% voltage drop
XXXX
Highlighted Numbers denote wire with 194 °F (90 °C) insulation only.
NOTE:
Not to be used on a Ground Fault Circuit Interrupter (GFCI). If using an externally regulated generator, verify that the
voltage, Hertz and idle speed are appropriate to supply the drive.
Service Entrance
Panel
GND
GND
Use the service
entrance panel
ground ONLY.
DO NOT run ground wire separate.
Motor ground wire MUST be bundled with motor wires.
Pump
Motor
Содержание 5870205003C
Страница 1: ...Owner s Manual SubDrive15 20 30 50 MonoDrive MonoDriveXT Connect NEMA 3R ...
Страница 45: ...NOTES ...
Страница 46: ...SubDrive15 20 30 50 MonoDrive MonoDriveXT Connect NEMA 3R Manual del propietario ...
Страница 90: ...NOTAS ...
Страница 91: ...Manuel du propriétaire SubDrive15 20 30 50 MonoDrive MonoDriveXT Connect NEMA 3R ...
Страница 135: ...REMARQUES ...