SubDrive/MonoDrive Connect
12
Service Entrance
Panel
GND
GND
When possible DO NOT run drive input
power or motor wires in parallel with house wiring.
Avoid running out-building wires in parallel with motor wires.
Pump
Motor
GND
GND
Input
power
Motor
Separate input power and motor
wiring by at least 8" (20.3 cm)
GND
GND
DO NOT run input power
and motor wires together.
Separate by at least 8" (20.3 cm)
Motor
Output lead to motor to
exit house as soon as possible.
8"
20.3 cm
Input
power
Wire Routing
To ensure the best protection from interference with other devices, please observe the
following precautions: