10 Product data sheets according to the ErP directive
10.1 profi-air 250 flex
Manufacturer
FRÄNKISCHE Rohrwerke Gebr. Kirchner GmbH & Co. KG
Hellinger Straße 1, 97486 Königsberg/Germany
Type of product
profi-air 250 flex
Catalogue number
78304725
Additional equipment
none
Specific energy consumption
SEC
cold
–78.5
[kWh/(m² a)]
average
–39.4
warm
–14.3
Energy efficiency grade
A
Type
RVU / BVU
Type of drive
VSD
Type of heat recovery
recuperation
Thermal efficiency
η
t
92
[%]
Highest airflow rate
250
[m³/h]
Electric power input
170
[W]
Sound power level
L
WA
46
[dB[A]]
Reference airflow rate
0.049
175
[m³/s]
[m³/h]
Reference pressure difference
50
[Pa]
Specific power input
SPI
0.24
[W/(m³/h)]
Control typology
time control (no demand control)
Control factor
0.95
Highest internal air leakage rate
1.4
[%]
Highest external air leakage rate
1.7
[%]
Location and description of filter warning indicator
fault report indicator on the control panel (visual)
Website
www.fraenkische.com
Annual energy consumption
AEC
cold
8.53
[kWh/(m² a)]
average
3.16
warm
2.71
Annual heating energy savings
AHS
cold
91.1
[kWh/(m² a)]
average
46.6
warm
21.0
Содержание profi-air 250/360 flex
Страница 104: ...Installation and operating instructions profi air 250 360 flex 104 Notes...
Страница 105: ...Installation and operating instructions profi air 250 360 flex 105 Notes...
Страница 106: ...Installation and operating instructions profi air 250 360 flex 106 Notes...
Страница 107: ...Installation and operating instructions profi air 250 360 flex 107 Notes...