Construction Hoist Fraco SEH Premium Range
Assembly and Operating Manual
Page 41 of 69
doc no. 98030718-01
8.2 Safety
inspection
Before start of work
-Carry out a test run with an
empty
car
-Check if there are any obstacles in the path of the car, for the entire length of travel.
The car will stop immediately if
-
An EMERGENCY STOP button is pressed.
-
A landing gate is open .
-
The extreme HI or extreme LOW limit switch is actuated.
-
The car has reached the mast end.
-
The buffer limit switches are actuated.
-
The security brake is engaged.
-
The roof hatch is opened.
-
The ground fault protection is activated.
The car will not start if
-
It is weight overloaded (warning light on car control is flashing).
-
A sliding gate or door is open or closed but not locked.
-
The over speed safety brake has triggered.
-
An EMERGENCY STOP button is pressed.
-
A landing gate is open.
-
The extreme HI or extreme LOW limit switch is actuated.
-
The car has reached the mast end.
-
The buffer limit switches are actuated.
-
The security brake is engaged.
-
The roof hatch is opened.
-
The ground fault protection is activated.
-
There is a drive fault (Button Reset AC drive is lighted)
A sliding door may only be opened if
-
The car is on the ground or stationary at a landing level.