Running cables
We recommend star wiring. A five core 0,6mm
cable (DC519) is run from the control panel to
most devices. Exceptions are the motor cables
which are 3 core 1mm, and AK sets mains supply
cable (3 core 5A). Lock and lamp cables may also
differ, so check their cable specifications.
Cables should enter the panel through glands.
Running the cables behind the PCB keeps the
limited space tidy. It is better to hide cables than
cut them too short. Mark all cables.
The wiring plan below shows individual cables
grouped in appropriate ducts. Only one junction
box is shown. Others are likely to be required.
Capital letters refer to the terminal they service.
An intercom has been included as an example of
access control. Devices on terminals L, K, G, E
and D are optional and not included in AXEL sets.